Steps
1
Remove the start capacitor and use a screwdriver to shorten the two terminals and discharge the electricity from it.(Touching the screwdriver across the two terminals shorts/discharges the capacitors stored energy). See picture.Analog Meter
- 1Set your analog meter on 1k ohms.
- 2Touch the two terminals with your ohms meter test leads. See picture.
- 3Reverse the way that you were touching the two terminals with your ohms meter test leads.
- The needle in your meter should swing to 0 ohms and swing back to infinity every time that you reverse the ohms meter test lead on the start capacitor. See picture.
- If it does that, the start capacitor is good.
Sumber : http://www.wikihow.com/Check-a-Start-Capacitor